Section 15.48.110 Noise and vibration.

    The following minimum noise and vibration standards must be complied with:
    A.    Noise.
    1.    For purposes of measuring the intensity of frequency of sound, the sound level meter, the octave band analyzer, and the impact noise analyzer shall be employed. The "C" network and the "slow" meter response of the sound level meter shall be used. Sounds of short duration, such as forge hammers, punch presses, etc., which cannot be measured accurately with the sound level meter shall be measured with the impact analyzer as manufactured by the General Radio Company, or its equivalent in order to determine the peak value of the impact.
    2.    The sound pressure level resulting from any activity, whether open or enclosed, shall not exceed, at any point on or beyond any lot line, the maximum permitted decibel levels for the octave band as set forth in the following table:

    Maximum Permitted Sound Pressure Level
    (in decibels)
    33 20 to 33 75    79
    13 75 to 1 100    74
    1 150 to 1 300    66
    1 300 to 1 600    59
    1 600 to 1200    53
    1200 to 2400    47
    2400 to 4800    41
    Above 4800    39

    B.    Vibration.
    1.    No activity shall cause or create a steady state of vibration at any point on any lot line, with a displacement in excess of the permitted steady state vibration displacement for the frequencies as set forth in the following table:

    Maximum Permitted Steady State Vibration
    Displacement (in inches)
Frequency
(cycles per second)
    10 and below    .0008
    10--20    .0005
    20--30    .0003
    30--40    .0002
    40--50    .0001
    50--60    .0001
    60 and over    .0001

    2.    No activity shall cause or create an impact vibration, at any point on any lot line, with a displacement in excess of the permitted impact vibration displacement for the frequencies as set forth in the following table:

    Maximum Permitted Impact Vibration
    Displacement (in inches)
Frequency
(cycles per second)    MI
    10 and below    .0016
    10--20    .0010
    20--30    .0006
    30--40    .0004
    40--50    .0002
    50--60    .0002
    60 and over    .0002
(Prior code § 19-1-11)
15.48.110